■ Product Overview
VS series water cooled generator within dedicated leakage current tester adopts medium frequency doubler circuit, PWM pulse width modulation technology and high-power IGBT device, and according to the theory of electromagnetic compatibility, the use of special shielding, isolation and grounding measures, such as the water cooled generator within dedicated leakage current tester to achieve the high quality, portable and can withstand the rated voltage discharge without damage.
■ Technical parameters
Technical parameters | 60/200 | 60/400 | 80/200 | 80/300 | 90/300 | 100/500 |
Output voltage kV | 60 | 60 | 80 | 80 | 90 | 100 |
Output current mA | 200 | 400 | 200 | 300 | 300 | 500 |
Output power W | 12000 | 24000 | 16000 | 24000 | 27000 | 50000 |
Voltage measurement error | ≤1.0% ±The two words | |||||
Current measurement error | ≤1.0% ±The two words | |||||
Overvoltage setting error | ≤1.0% | |||||
Ripple coefficient | ≤3.0% | |||||
Voltage stability | ≤1.0% | |||||
The power supply voltage | AC380V(Three phase four wire) | |||||
The case of weight | 25.0 kg | 25.0kg | ||||
Voltage double weight | 65.0kg | 70.0kg |