■ functional features of transformer on load switch AC / DC parameter tester
▲ the instrument has large output current, light weight and easy to carry.
▲ the instrument outputs an open circuit voltage of 28V. It can test the transition resistance of 10 Ω under the current of 1A gear, and is equipped with 0.5A and 0.3A gears to facilitate the test of larger transition resistance.
▲ it has perfect protection circuit and strong reliability.
▲ vertical chassis structure, 5.7-inch large LCD display, convenient for field operation.
▲ with U disk storage function, more data waveforms can be stored.
■ technical parameters
▲ output current: 1.0A, 0.5A, 0.3A, three gears optional
▲ resistance range: 0.1 ~ 10 Ω at 1.0A; 0.5A gear 5 ~ 20 Ω; 0.3A gear 10 ~ 40 Ω
▲ resistance measurement accuracy: ± (reading) × 5% ± 5 words), resolution: 0.01 Ω
▲ measurement range of transition time: 1 ~ 250ms
▲ measurement accuracy of transition time: ± 1ms, resolution: 0.1ms
▲ sampling frequency: 10kHz
▲ storage mode: USB flash disk storage and local storage
▲ working temperature: - 20 ℃ ~ + 50 ℃
▲ ambient humidity: ≤ 90% RH, no condensation
▲ working power supply: AC220V ± 10%, 50Hz ± 10%