MV28-VLF Cable ultra low frequency dielectric loss

Mv28-vlf cable ultra-low frequency dielectric loss is a truly compact and portable ultra-low frequency test system for testing medium and low voltage cables. The instrument can be applied to the withstand voltage of cables below 6kV, dielectric loss and partial discharge of cables below 10kV. The instrument itself integrates the dielectric loss diagnosis system, and has various test functions such as cable withstand voltage test, outer sheath test, outer sheath fault location, DC test, dielectric loss test, etc. at the same time, the instrument is a lighter cable tester in the world, which integrates withstand voltage and dielectric loss test, and the peak voltage can reach 28kv.

Tel:0086+400-996-1868

Ultra low frequency dielectric loss of mv28-vlf cable

■ Product introduction

Mv28-vlf cable ultra-low frequency dielectric loss is a truly compact and portable ultra-low frequency test system for testing medium and low voltage cables. The instrument can be applied to the withstand voltage of cables below 6kV, dielectric loss and partial discharge of cables below 10kV. The instrument itself integrates the dielectric loss diagnosis system, and has various test functions such as cable withstand voltage test, outer sheath test, outer sheath fault location, DC test, dielectric loss test, etc. at the same time, the instrument is a lighter cable tester in the world, which integrates withstand voltage and dielectric loss test, and the peak voltage can reach 28kv.

■ Technical parameter

Input voltage100~240 V 50/60 Hz (400 V A)
output voltage

Sinusoidal: 0 ~ 28 kV peak value, 20 kV effective value DC: ± 0 ~ 28 kV

Square wave: 28 kV, accuracy: ± 1%, resolution: 0.1kv

Output current0 ~ 20 MA (resolution 1) μ A) Accuracy: ± 1%
Resistance range0.1 MΩ~5GΩ
output frequency0.01 ~ 0.1 Hz, each step 0.01 Hz (default 0.1 Hz) ~ automatic frequency selection
Sheath testTest voltage: 10 kV Current: 0.1 Ma ~ 5.0 Ma
Test mode

AC (VLF) in the whole range, symmetrical and load independent, DC (positive or negative),

Recording / fault condition or fault trip mode, sheath / sheath test

MeasureVoltage and current (true RMS and / or peak), capacitance, resistance, time, flashover voltage
Dielectric loss accuracy± 1 x 10 -4