Products
Your location:home page > Products > Complete set of comprehensive series of power equipment > VSJC-L100 Impulse current generator

VSJC-L100 Impulse Current Generator

▲ It can output the square wave current 2000μs specified by the standard and can measure the residual pressure of the sample.▲ It can output the standard lightning impulse current 4/10μs, lightning impulse current 8/20μs, steep wave impulse current 1/20μs, operating impulse current 30/80μs and square wave current waveform and can measure the residual voltage of the sample.▲ The residual voltage of the sample corresponding to the required waveform and current is less than 10kV.

Tel:0086+400-996-1868

■ Features

▲ It can output the square wave current 2000μs specified by the standard and can measure the residual pressure of the sample.

▲ It can output the standard lightning impulse current 4/10μs, lightning impulse current 8/20μs, steep wave impulse current 1/20μs, operating impulse current 30/80μs and square wave current waveform and can measure the residual voltage of the sample.

▲ The residual voltage of the sample corresponding to the required waveform and current is less than 10kV.

■ Technical parameters

▲ Square wave impulse current

       Waveform: 2000μs, 2400μs

       Maximum current: 1.5±5% kA

▲ Lightning impacts high current

       Waveform: (3.5 to 4.5)/(9 to 11) µs

       Maximum current: 100±5% kA

       Reverse polarity oscillation peak is less than 20% of current peak

▲ Lightning impulse current

       Waveform: (7 ~ 9)/(18 ~ 22) µs

       Maximum current: 40±5% kA

       Reverse polarity oscillation peak is less than 20% of current peak

▲ Steep wave impulse current

       Waveform: (0.9 ~ 1.1)/(18 ~ 22) µs

       Maximum current: 10±5% kA

▲ Operating impulse current

       Waveform: 30/80µs

       Maximum current: 40±5% kA

▲ Impulse current

       Waveform: 18/40µs

       Maximum current: 20±5% kA

▲ Rated value

1) 8 sets of 50kV/8μF pulse capacitors

       Rated voltage: ±50kV

       Rated capacity: 64μF

       Rated energy: 80kJ

2) 8 sets of 50kV/8μF pulse capacitors, two series and four parallel, rated voltage: ±100kV

       Rated capacity: 16μF

       Rated energy: 80kJ

3) 10 sets of 35kV/8μF pulse capacitor rated voltage: ±35kV

       Rated capacity: 80μF

       Rated energy: 49kJ

4) Current waveform and amplitude: 4/10μS positive and negative lightning impulse current waveform, amplitude 100kA; 8/20μS positive and negative polarity operating impulse current waveform, amplitude 40kA; wave head time 1μS steep impulse current waveform , Amplitude 20kA; 30/80μS positive and negative polarity operating impulse current, amplitude 2kA; 2ms square wave impulse current, amplitude 1.5kA, 18/40μS impulse current, amplitude 20kA, waveform deviation does not exceed IEC and national standards Waveform requirements

5) Duration of use: >70%In can be charged and discharged every 90 seconds for continuous operation >70%, <70%In can be charged and discharged every 60 seconds for continuous operation

 

  • Mobile browsing

    Mobile browsing

  • Wechat attention

    Wechat attention

HomeTelProduct